HOT POST

50/recent/ticker-posts

Header Ads Widget

SOP for Cleaning Procedure of Empty PVC Bottles

OBJECTIVE
To lay down a procedure for cleaning of empty PVC Bottles.

SCOPE
This procedure applies for Beta-Lactam production department in Pharmaceutical Manufacturing Facilities of XYZ Limited, Formulation division. This procedure covers cleaning of empty PVC bottles.

RESPONSIBILITY
The beta-lactam dry syrup filling operator is responsible for implementation of the process.
The Beta-Lactam In-Charge is responsible for the execution and compliance of the procedure.


PROCEDURE
1 Carry the bottles to the bottles inspection area, unload and inspect them and reject damaged bottles before sending for cleaning.
2 Turn on the compressor and switch ON the blower and check that dry air is blown.
3 Hold the bottles in inverted, upside down position on the blower neck and pass dry compressed air in the bottles.
4 Switch OFF the blower and compressor.
5 Visually inspect the bottles after blowing and reject any damaged or uncleaned bottles.
6 Check the bulb and remove water collected from the compressed air with line.
7 Take these cleaned bottles to the filling area, and use for filling of dry syrup.
8 The balance of the remaining bottles should be return to the store.
9 Check the pressure and compressor valves for leakage daily.

ABBREVIATION(s)
Q.A : Quality Assurance
BL : Beta-Lactam
SCP : Standard Cleaning Procedure
No. : Number
P.D : Production
PVC : Poly vinyl chloride

ANNEXURE(s)
Nil.

REVISION HISTORY
Nil